Host under test: win2025test (Tailscale 100.127.62.31), Windows Server 2025 Standard, build 10.0.26100, 64-bit. Access: SSH (key-based, Administrator) from the OpenClaw Linux host, driving cscript/powershell remotely. Site: WscMvc, binding *:8090, physical path C:\Projects\wsc-mvc, app pool WscMvc (64-bit, no managed code). Date: 2026-09-19.

M0 — Environment and feasibility

Check Result
Windows version / arch PASS — Server 2025 Standard, 10.0.26100, 64-bit
IIS + Classic ASP (Web-ASP) + CGI/ISAPI installed PASS
URL Rewrite module installed PASS (rewrite.dll registered as global module)
WebAdministration PowerShell module PASS (v1.0.0.0)
WSC/COM runtime (scrobj.dll) present PASS (System32 and SysWOW64)
regsvr32/cscript/wscript present PASS
Minimal WSC register/instantiate/call/unregister/re-register outside IIS PASS — see M1 component tests below (folded into M1 since the same components serve both gates)

Command: cscript //nologo tests\Test-Components.vbs — see M1.

M1 — Vertical HTTP slice

WSH component smoke test

Command:

cscript //nologo C:\Projects\wsc-mvc\tests\Test-Components.vbs

Result: PASS

PASS: /hello -> 200 OK | text/html; charset=utf-8 | Hello from WSC-MVC!
PASS: unknown route -> 404 Not Found
RESULT: ALL PASS

HTTP integration test

Command:

powershell -File C:\Projects\wsc-mvc\tests\Test-Http.ps1 -BaseUrl http://localhost:8090

Result: PASS

PASS: GET /hello status 200
PASS: GET /hello content-type
PASS: GET /hello body
PASS: GET /Framework/Application.wsc denied
RESULT: ALL PASS

Also verified directly from the Linux host over the tailnet:

curl -i http://100.127.62.31:8090/hello

-> HTTP/1.1 200 OK, Content-Type: text/html; charset=utf-8, body Hello from WSC-MVC!. PASS

Direct source/config access denied

GET /Framework/Application.wsc (and by the same hiddenSegments mechanism, Controllers/, tests/, tools/, docs/) -> 404 Not Found. PASS (covered by Test-Http.ps1 above for the .wsc case; other directories share the identical web.config rule and were not individually re-tested by automated script, only spot-checked manually).

Safe failure on broken/missing registration

Steps: unregister both components -> request /hello -> observe safe 500 with no leaked path/exception -> re-register -> confirm recovery.

  • From the VM itself (curl http://localhost:8090/hello while unregistered): HTTP/1.1 500 Internal Server Error, Content-Type: text/plain; charset=utf-8, body exactly Internal Server Error (our own Default.asp error branch). PASS
  • From a remote/tailnet client under the same unregistered condition: HTTP/1.1 500 Internal Server Error with IIS's own generic friendly-error HTML (no path/exception content either). PASS — see docs/DECISIONS.md for why local vs. remote differ (IIS httpErrors errorMode=DetailedLocalOnly, expected default behavior, not a bug).
  • cscript //nologo tests\Test-Components.vbs while unregistered: FAIL: could not create WscMvc.Application - ActiveX component can't create object (test script correctly reports FAILURE, exit code 1 — this is the expected result of this specific check, proving the failure path is real and detectable, not silently swallowed).
  • After tools\Register-Components.ps1: HTTP and WSH tests both back to PASS (shown above).

Reversible unregistration

Command sequence:

powershell -File tools\Register-Components.ps1
powershell -File tools\Unregister-Components.ps1
powershell -File tools\Register-Components.ps1

Result: PASS, but only after a fix — see docs/DECISIONS.md finding on regsvr32 /s /u not actually removing .wsc registry entries on this host. tools\Unregister-Components.ps1 now verifies and, when needed, explicitly removes exactly this project's ProgID/CLSID pair. Confirmed via direct registry inspection (HKLM:\SOFTWARE\Classes\WscMvc.Application / WscMvc.HomeController and their CLSID subtrees) before and after each step, not just exit codes.

Concurrency (basic)

Command: two curl requests to http://100.127.62.31:8090/hello fired in parallel from bash (& + wait). Result: PASS — both returned 200, both bodies exactly Hello from WSC-MVC!, no cross-request leakage or interference observed. This is a basic smoke check only, not a load test (out of scope for M1).

Not yet run / out of scope for M1

  • Formal 400/405 method-not-allowed handling — routing table doesn't exist until M3.
  • Broader concurrency/load testing — deferred to M6 per IMPLEMENTATION_PLAN.
  • 32-bit app-pool path — not exercised; all app pools on this host are 64-bit and no 32-bit requirement has appeared. Revisit if a future dependency needs 32-bit COM.

M1 gate status: PASS

All SPEC §14 acceptance criteria for M1 were run on real Windows/IIS (not inferred) and passed, including one real defect found and fixed during testing (unregistration). Proceeding to M2 (lifecycle/error-handling generalization) is unblocked.