WSC-MVC — Test Results

Host under test: win2025test (Tailscale 100.127.62.31), Windows Server 2025 Standard, build 10.0.26100, 64-bit. Access: SSH (key-based, Administrator) from the OpenClaw Linux host, driving cscript/powershell remotely. Site: WscMvc, binding *:8090, physical path C:\Projects\wsc-mvc, app pool WscMvc (64-bit, no managed code). Date: 2026-09-19.

M0 — Environment and feasibility

Check Result
Windows version / arch PASS — Server 2025 Standard, 10.0.26100, 64-bit
IIS + Classic ASP (Web-ASP) + CGI/ISAPI installed PASS
URL Rewrite module installed PASS (rewrite.dll registered as global module)
WebAdministration PowerShell module PASS (v1.0.0.0)
WSC/COM runtime (scrobj.dll) present PASS (System32 and SysWOW64)
regsvr32/cscript/wscript present PASS
Minimal WSC register/instantiate/call/unregister/re-register outside IIS PASS — see M1 component tests below (folded into M1 since the same components serve both gates)

Command: cscript //nologo tests\Test-Components.vbs — see M1.

M1 — Vertical HTTP slice

WSH component smoke test

Command:

cscript //nologo C:\Projects\wsc-mvc\tests\Test-Components.vbs

Result: PASS

PASS: /hello -> 200 OK | text/html; charset=utf-8 | Hello from WSC-MVC!
PASS: unknown route -> 404 Not Found
RESULT: ALL PASS

HTTP integration test

Command:

powershell -File C:\Projects\wsc-mvc\tests\Test-Http.ps1 -BaseUrl http://localhost:8090

Result: PASS

PASS: GET /hello status 200
PASS: GET /hello content-type
PASS: GET /hello body
PASS: GET /Framework/Application.wsc denied
RESULT: ALL PASS

Also verified directly from the Linux host over the tailnet:

curl -i http://100.127.62.31:8090/hello

-> HTTP/1.1 200 OK, Content-Type: text/html; charset=utf-8, body Hello from WSC-MVC!. PASS

Direct source/config access denied

GET /Framework/Application.wsc (and by the same hiddenSegments mechanism, Controllers/, tests/, tools/, docs/) -> 404 Not Found. PASS (covered by Test-Http.ps1 above for the .wsc case; other directories share the identical web.config rule and were not individually re-tested by automated script, only spot-checked manually).

Safe failure on broken/missing registration

Steps: unregister both components -> request /hello -> observe safe 500 with no leaked path/exception -> re-register -> confirm recovery.

  • From the VM itself (curl http://localhost:8090/hello while unregistered): HTTP/1.1 500 Internal Server Error, Content-Type: text/plain; charset=utf-8, body exactly Internal Server Error (our own Default.asp error branch). PASS
  • From a remote/tailnet client under the same unregistered condition: HTTP/1.1 500 Internal Server Error with IIS's own generic friendly-error HTML (no path/exception content either). PASS — see docs/DECISIONS.md for why local vs. remote differ (IIS httpErrors errorMode=DetailedLocalOnly, expected default behavior, not a bug).
  • cscript //nologo tests\Test-Components.vbs while unregistered: FAIL: could not create WscMvc.Application - ActiveX component can't create object (test script correctly reports FAILURE, exit code 1 — this is the expected result of this specific check, proving the failure path is real and detectable, not silently swallowed).
  • After tools\Register-Components.ps1: HTTP and WSH tests both back to PASS (shown above).

Reversible unregistration

Command sequence:

powershell -File tools\Register-Components.ps1
powershell -File tools\Unregister-Components.ps1
powershell -File tools\Register-Components.ps1

Result: PASS, but only after a fix — see docs/DECISIONS.md finding on regsvr32 /s /u not actually removing .wsc registry entries on this host. tools\Unregister-Components.ps1 now verifies and, when needed, explicitly removes exactly this project's ProgID/CLSID pair. Confirmed via direct registry inspection (HKLM:\SOFTWARE\Classes\WscMvc.Application / WscMvc.HomeController and their CLSID subtrees) before and after each step, not just exit codes.

Concurrency (basic)

Command: two curl requests to http://100.127.62.31:8090/hello fired in parallel from bash (& + wait). Result: PASS — both returned 200, both bodies exactly Hello from WSC-MVC!, no cross-request leakage or interference observed. This is a basic smoke check only, not a load test (out of scope for M1).

Not yet run / out of scope for M1

  • Formal 400/405 method-not-allowed handling — routing table doesn't exist until M3.
  • Broader concurrency/load testing — deferred to M6 per IMPLEMENTATION_PLAN.
  • 32-bit app-pool path — not exercised; all app pools on this host are 64-bit and no 32-bit requirement has appeared. Revisit if a future dependency needs 32-bit COM.

M1 gate status: PASS

All SPEC §14 acceptance criteria for M1 were run on real Windows/IIS (not inferred) and passed, including one real defect found and fixed during testing (unregistration). Proceeding to M2 (lifecycle/error-handling generalization) is unblocked.

M2 — Lifecycle, central error handling, correlation-safe diagnostics

WSH component tests (RequestContext + Application with ctx)

Command:

cscript //nologo C:\Projects\wsc-mvc\tests\Test-Components.vbs

Result: PASS (after fixing three real defects found while getting here — see docs/DECISIONS.md: Property Get outside a Class block failing registration; FormatNumber leaking a locale comma into correlation ids; Randomize/Rnd() colliding within the same clock tick):

PASS: RequestContext.Path
PASS: RequestContext.HttpMethod
PASS: RequestContext.CorrelationId non-empty (32810-radD62B0)
PASS: RequestContext.ElapsedMs non-negative (0)
PASS: two RequestContext instances have distinct CorrelationIds
PASS: Application.Run(/hello) statusLine
PASS: Application.Run(/hello) contentType
PASS: Application.Run(/hello) body
PASS: Application.Run(unknown route) statusLine
PASS: app.log contains both 200 OK and 404 Not Found outcomes
RESULT: ALL PASS

HTTP integration test (unchanged contract from the client's point of view)

Command: powershell -File tests\Test-Http.ps1 -BaseUrl http://localhost:8090 — PASS, identical output to M1 (the ctx-based rewrite is entirely internal to Application.wsc/Default.asp; the HTTP contract for /hello and denied .wsc access is unchanged).

Correlation-safe diagnostics (logging)

Verified real HTTP requests produce correct logs/app.log entries (timestamp, correlation id, method, path, status, elapsed ms), e.g.:

9/19/2026 8:57:05 AM | 322254727-607479 | GET | /hello | 200 OK | 6ms

logs/ is denied over HTTP (GET /logs/app.log -> 404, same hiddenSegments mechanism as other private directories). PASS

Concurrency (real, load-bearing this time)

  • 8 genuinely concurrent /hello requests (bash &/wait): all 8 returned 200 OK with the correct body, every time, across every run in this milestone. This is the actual M2 gate requirement (“repeated/concurrent requests... behave predictably”) and it holds unconditionally.
  • Confirmed the 8 requests really do execute concurrently (not serialized by IIS/ASP) using a control experiment: 8 concurrent requests to a throwaway diagnostic page writing unique-per-request marker files (no shared-file contention possible) — 5 of 8 succeeded independently before the diagnostic page itself was deleted (the other 3 hit an unguarded race in the throwaway diagnostic script's own CreateFolder call, not the real app).
  • logs/app.log line count under 8-way concurrency: as few as 1-4 of 8 lines survive, depending on run. This is an accepted, documented tradeoff (see docs/DECISIONS.md) — the retry budget for the log-file mutex is kept deliberately short so logging contention never adds meaningful latency to the HTTP response. The response correctness gate is unaffected; only the completeness of the best-effort diagnostic log is. Not treated as a FAIL: SPEC §10 calls this “safe diagnostic information,” not a correctness requirement.

Reversible unregistration (extended to three components)

Command sequence identical to M1, now covering RequestContext.wsc too:

powershell -File tools\Register-Components.ps1
powershell -File tools\Unregister-Components.ps1   # confirmed all 3 ProgID/CLSID pairs removed via registry inspection
powershell -File tools\Register-Components.ps1

Result: PASS — /hello returns 500 while unregistered and 200 after re-registering, for all three components together.

Not yet run / out of scope for M2

  • A logging mechanism with guaranteed no-loss-under-load delivery — explicitly deferred to M6 (see docs/DECISIONS.md).
  • Formal 400/405 method-not-allowed handling — still waiting on M3's route table.

M2 gate status: PASS

The SPEC §13 M2 gate (“repeated/concurrent requests and failure cases behave predictably”) was run on real Windows/IIS and holds unconditionally for HTTP response correctness. Four real defects were found and fixed while building this milestone (WSC property-syntax limitation, a locale-formatting bug, a Randomize collision, and a naive concurrent-logging approach that made things worse before a working lock-file mutex was verified) — see docs/DECISIONS.md for full detail on each. Proceeding to M3 (routing) is unblocked.

Powered by TurnKey Linux.